Waste disposal autoclave

Garbage disposal autoclave

Autoclave device for disposal of hospital waste

From size 150 to 5000 liters

Approved by the Environmental Protection Organization of the country

Certified by the accredited laboratory of the Environmental Protection Organization of the country

The special program for decontamination of hospital infectious medical waste at a temperature of 138 degrees Celsius for 30 minutes.

Has a room temperature sensor

With a jacket temperature sensor

Fully automatic

Standing rectangular autoclave with peri-vacuum system (pre-vacuum)

Reducing the amount of waste by about 60%

Two doors with interlock system to separate sterile from non-sterile space

Horizontal and vertical doors according to size and order

For using central steam and electric steam generator (dual purpose)

It has a thermal jacket to equalize the heat and minimize condensation inside the chamber.

All jacket and chamber designs are based on ASME SECTION VIII code

All weldings are based on AWS standard code. ASME CODE SECTION IX

Chamber made of AISI S.ST 316 L stainless steel, anti-rust, anti-acid, 6 mm thick

The door of the machine is made of stainless steel AISI S.ST 316 L, anti-rust, anti-acid, 6 mm thick.

The material of the jacket is stainless steel AISI S.ST 304 with a thickness of 4 mm.

The panels of the device are made of AISI S.ST 304 stainless steel with a thickness of 1 mm. All the stainless steel sheets used have a material analysis sheet from Razi Metallurgical Laboratory.

Disinfectant of hospital or pharmaceutical infectious waste
Specifications:
Autoclave device for disposal of hospital waste
From size 150 to 5000 liters
Certified by the Environmental Protection Organization of the country
Certified by the accredited laboratory of the Environmental Protection Organization of the country
Special program for decontamination of hospital infectious medical waste at a temperature of 138 degrees Celsius for 30 minutes.
Has a room temperature sensor
With a jacket temperature sensor

Fully automatic

Standing rectangular autoclave with peri-vacuum (pre-vacuum) system

Reducing the amount of waste by about 70%

Two doors with interlock system to separate sterile from non-sterile space

Horizontal and vertical doors according to size and order

To use central steam and electric steam generator (dual purpose)

Has a thermal jacket to equalize heat and minimize condensation inside the chamber.

All jacket and chamber designs based on VIII SECTION ASME code

All weldings are based on the IX SECTION CODE ASME .AWS standard code

Chamber made of L 316 ST.S AISI stainless steel, anti-rust, anti-acid, 6 mm thick

The door of the device is made of stainless steel L 316 ST.S AISI, anti-rust, anti-acid, 6 mm thick.

The material of the jacket is 4 mm thick AISI 304 ST.S stainless steel.

The panels of the device are made of AISI 304 ST.S stainless steel with a thickness of 1 mm. All the stainless steel sheets have leaves.

Material analysis is done by Razi Metallurgical Laboratory.

Description

Hospital infectious waste safe autoclave, also known as amha autoclave, is an industrial device for

It is designed to sterilize and disinfect infectious and hospital waste. This device is especially suitable for health and treatment centers

Hazardous and infectious waste management is used.

Reduction of volume and weight: autoclaving waste reduces their volume by 80% and their weight by 30%, which makes transportation and

It makes it easier to quote them

Decontamination: This device destroys bacteria, fungi and infectious agents in the waste, but it does not completely destroy the waste.

does not

Compared to incinerators, which burn waste and may produce pollutants such as toxic fumes, autoclaves only

Makes waste safe without burning it. This feature makes the autoclave a more suitable option for management

Infectious wasteThe sterile autoclave for infectious waste is a vital tool in medical waste management by providing a safe and effective method.
It helps to protect public health and the environment for the safe disposal of waste

 

Reviews

There are no reviews yet.

Be the first to review “Waste disposal autoclave”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Be the first to review “Waste disposal autoclave”

Your email address will not be published. Required fields are marked *